Inlet A(in):1-1/8; Outlet B(in):1-1/8; Overall dimensions(mm) C:100; D:325; h:53; H:591; d:11x22; E:316; F:350; Cubage:39.6L;
The function of the liquid receiver is used to store the liquid of refrigerant evaporator.When the system is maintenanced, refrigerant can also be stored in the liquid receiver .Liquid receiver tank size according to the refrigerant filling quantity in the system.You can check the following technical data for choosing the most suitable liquid receiver for your system.
Characteristics and Advantages
Can customized the special liquid receiver according to your requirements..
Design for storage refrigerants during normal operation and system maintenance.
Allows the system to adjust to adapt to the different conditions and load system.
Structure design for vertical and horizontal optional.
Available for selection: sight glassr, cut-off valve,mounting bracket, the welding joint, flare connection, the safety valve connection , fusible plug, etc.
Surface is with corrosion resistant epoxy powder coating.
Product introduction
The main body adopts cold-rolled sheet tensile structure design
The outlet is equipped with cut-off valve,inlet use flare or ODF connection.
In order to achieve the best operation, the liquid receiver should be installed vertically
Maximum working pressure 35 bar
Inlet A(in):1-1/8;
Outlet B(in):1-1/8;
Overall dimensions(mm) C:100; D:325; h:53; H:591; d:11x22; E:316; F:350;
Cubage:39.6L;