AL Series Sequencer, field proven for controlling the operation of heating elements and/or blower motors in electric, gas or oil heat systems. This sequencer has 1 switch & turns on at 1-60 seconds, and off at 1-45 seconds.
AL Series Sequencer, field proven for controlling the operation of heating elements and/or blower motors in electric, gas or oil heat systems. This sequencer has 1 switch & turns on at 1-60 seconds, and off at 1-45 seconds.
●Direct Replacement for Most Fan & Heat Sequencing Functions.
●240 Volt Input Control .
●Contacts Designated M1-M2 of a Multi-timing Sequencer will Turn On First and Turn Off Last, as Required by UL for Electric Heating Applications.
●Five Second on Delay Between all Subsequent Stages, Unless they Function Together.
Applications:Oil furnaces,Gas furnaces,Heat pumps,Electric furnaces
Replacement Part: Mars 33243;KLIXON 6000AOM ;White Rodgers 24A51-1
Off:1 - 45 Seconds;
On:1 - 60 Seconds;
Sequencer Wiring Diagram
*Note all Sequencers include a 24 volt heater except the AL113 which has a 240 volt heater.