Cable Length (feet): 100; Min power output at 40°F (5°C) on pipe (watts): 600; Nominal power output in ice and snow (watts): 800; Nominal Cable Width (in): 0.5; Nominal Cable Thickness (in): 0.236; Heating Cable Bus Wire Gauge (AWG): .16; Cold Lead Length (in): 30; Voltage Rating (v): 110-120; Plug Rating (amps): 15; Circuit Breaker Sizing Minimum (amps): 15; Max. Exposure Temperature: 150°F(65°C); Electrical Classification: Nonhazardous areas only; Exposure To Chemicals: None
Cable Length (feet): 75; Min power output at 40°F (5°C) on pipe (watts): 450; Nominal power output in ice and snow (watts): 600; Nominal Cable Width (in): 0.5; Nominal Cable Thickness (in): 0.236; Heating Cable Bus Wire Gauge (AWG): .16; Cold Lead Length (in): 30; Voltage Rating (v): 110-120; Plug Rating (amps): 15; Circuit Breaker Sizing Minimum (amps): 15; Max. Exposure Temperature: 150°F(65°C); Electrical Classification: Nonhazardous areas only; Exposure To Chemicals: None
Cable Length (feet): 50; Min power output at 40°F (5°C) on pipe (watts): 300; Nominal power output in ice and snow (watts): 400; Nominal Cable Width (in): 0.5; Nominal Cable Thickness (in): 0.236; Heating Cable Bus Wire Gauge (AWG): .16; Cold Lead Length (in): 30; Voltage Rating (v): 110-120; Plug Rating (amps): 15; Circuit Breaker Sizing Minimum (amps): 15; Max. Exposure Temperature: 150°F(65°C); Electrical Classification: Nonhazardous areas only; Exposure To Chemicals: None
Cable Length (feet): 24; Min power output at 40°F (5°C) on pipe (watts): 144; Nominal power output in ice and snow (watts): 192 ; Nominal Cable Width (in): 0.5; Nominal Cable Thickness (in): 0.236; Heating Cable Bus Wire Gauge (AWG): .16; Cold Lead Length (in): 30; Voltage Rating (v): 110-120; Plug Rating (amps): 15; Circuit Breaker Sizing Minimum (amps): 15; Max. Exposure Temperature: 150°F(65°C); Electrical Classification: Nonhazardous areas only; Exposure To Chemicals: None
Cable Length (feet): 18; Min power output at 40°F (5°C) on pipe (watts): 108; Nominal power output in ice and snow (watts): 144 ; Nominal Cable Width (in): 0.5; Nominal Cable Thickness (in): 0.236; Heating Cable Bus Wire Gauge (AWG): .16; Cold Lead Length (in): 30; Voltage Rating (v): 110-120; Plug Rating (amps): 15; Circuit Breaker Sizing Minimum (amps): 15; Max. Exposure Temperature: 150°F(65°C); Electrical Classification: Nonhazardous areas only; Exposure To Chemicals: None
Cable Length (feet): 12; Min power output at 40°F (5°C) on pipe (watts): 72; Nominal power output in ice and snow (watts): 96 ; Nominal Cable Width (in): 0.5; Nominal Cable Thickness (in): 0.236; Heating Cable Bus Wire Gauge (AWG): .16; Cold Lead Length (in): 30; Voltage Rating (v): 110-120; Plug Rating (amps): 15; Circuit Breaker Sizing Minimum (amps): 15; Max. Exposure Temperature: 150°F(65°C); Electrical Classification: Nonhazardous areas only; Exposure To Chemicals: None
Cable Length (feet): 6; Min power output at 40°F (5°C) on pipe (watts): 36; Nominal power output in ice and snow (watts): 48 ; Nominal Cable Width (in): 0.5; Nominal Cable Thickness (in): 0.236; Heating Cable Bus Wire Gauge (AWG): .16; Cold Lead Length (in): 30; Voltage Rating (v): 110-120; Plug Rating (amps): 15; Circuit Breaker Sizing Minimum (amps): 15; Max. Exposure Temperature: 150°F(65°C); Electrical Classification: Nonhazardous areas only; Exposure To Chemicals: None
Waterproof material-PU; Quality sewing of the material; Has a water external outlet to let you drain your water in a bucket ; Also in can be used as a dust cover; With a elastic strap, effectively protects your air conditioner ;
Waterproof material-PU; Quality sewing of the material.; Has a water external outlet to let you drain your water in a bucket.; Also in can be used as a dust cover.; With a elastic strap, effectively protects your air conditioner.