Pressure Range: 3P.S.I~700P.S.I; Settings P.S. Open: 200 ;Close: 150 ;Setting Tolerance: Open: +/-15 ;Close: +/-15 ;Additional: High Pressure Automatic Reset
Pressure Range: 3P.S.I~700P.S.I; Settings P.S. Open: 40 ;Close: 80 ;Setting Tolerance: Open: +/-5 ;Close: +/-5 ;Additional: Low Pressure Automatic Reset
Pressure Range: 3P.S.I~700P.S.I; Settings P.S. Open: 25 ;Close: 80 ;Setting Tolerance: Open: +/-5 ;Close: +/-5 ;Additional: Low Pressure Automatic Reset
Pressure Range: 3P.S.I~700P.S.I; Settings P.S. Open: 25 ;Close: 50 ;Setting Tolerance: Open: +/-5 ;Close: +/-5 ;Additional: Low Pressure Automatic Reset
Pressure Range: 3P.S.I~700P.S.I; Settings P.S. Open: 10 ;Close: 20 ;Setting Tolerance: Open: +/-5 ;Close: +/-5 ;Additional: Low Pressure Automatic Reset
Pressure Range: 3P.S.I~700P.S.I; Settings P.S. Open: 5 ;Close: 20 ;Setting Tolerance: Open: +/-5 ;Close: +/-5 ;Additional: Low Pressure Automatic Reset
The Liquid Flow Switches are single-Pole, Double-Throw (SPDT) flow switches that are used in liquid lines carrying water, ethylene glycol, or otherliquids not classified as hazardous.they can be wired to energize one device and de-energize another device powered from the same source when liquid flow either exceeds or drops below the set flow either exceeds or drops below the set flow rate.
Note: The Flow Switch Cannot be used where the liquid in the pipes will drip below the liquid’s freezing point, causing an internal freeze-up.
IMPORTANT:Flow Switches are designed for use ONLY as operating controls. Where an operating Control failure would result in personal injury and/or loss of property, it is the responsibility of the installer to add devices (safety, limit controls)or systems(alarm, supervisory systems)that protect against or warn of control failure.
The Liquid Flow Switches are single-Pole, Double-Throw (SPDT) flow switches that are used in liquid lines carrying water, ethylene glycol, or otherliquids not classified as hazardous.they can be wired to energize one device and de-energize another device powered from the same source when liquid flow either exceeds or drops below the set flow either exceeds or drops below the set flow rate.
Note: The Flow Switch Cannot be used where the liquid in the pipes will drip below the liquid’s freezing point, causing an internal freeze-up.
IMPORTANT:Flow Switches are designed for use ONLY as operating controls. Where an operating Control failure would result in personal injury and/or loss of property, it is the responsibility of the installer to add devices (safety, limit controls)or systems(alarm, supervisory systems)that protect against or warn of control failure.
A compact surge suppressor offering better surge protection levels.
50kA Maximum Surge Current, 120/240V AC Voltage Rating, 1-phase, 3-wire (isolated ground), NEMA 4X Enclosure Rating.